Al Rouf LED

Alrouf Diesel Generator Operated Light Towers


Warning Sign
Click the relevant product code in the table above to access the Flood Light (IES file) files and the installation instructions for your luminaire.

Diesel Generator Operated Light Towers | Light Tower Generator

Alrouf's Diesel Generator Operated Light Towers provide independent, generator-powered lighting for construction sites, industrial maintenance, infrastructure projects, and remote work areas. Available in five models with mast heights from 4 to 9 metres, these portable lighting towers combine diesel generators, adjustable lighting fixtures, and model-specific fuel capacities. The range supports temporary lighting requirements where permanent electrical power is unavailable.

Request a Quote

Key Features & Benefits

  • Independent diesel power: Provides temporary lighting without relying on a permanent electrical connection.
  • Adjustable mast heights: Five models offer mast heights from 4 to 9 metres for different worksite layouts.
  • Multiple fuel capacities: Tanks ranging from 16 to 74 litres support different operating requirements.
  • Sound-attenuated housing: Designed to reduce generator noise in working environments.
  • Flexible mast operation: Manual mast systems are available, while the LTK-H7 features hydraulic operation.
  • Directional lighting: Adjustable fixtures help position illumination across designated working areas.
  • Transportable configurations: Trailer arrangements, towing hitches, and lifting provisions support relocation between work areas.

Applications

  • Construction sites: Temporary lighting for night-time building and civil works.
  • Mining and quarrying: Lighting for remote operational and maintenance areas.
  • Industrial facilities: Temporary illumination during maintenance and shutdown activities.
  • Infrastructure projects: Lighting for roadworks and outdoor construction.
  • Agricultural operations: Temporary lighting for remote field activities.
  • Remote worksites: Generator-powered illumination where grid electricity is unavailable.

FQA

What is a diesel light tower generator?

A diesel light tower generator combines an engine-driven electrical generator, elevated lighting fixtures, and a movable support structure. It provides temporary illumination for construction, industrial, and remote operations where permanent electrical infrastructure is unavailable.

How long can a diesel light tower operate on a full tank?

The catalogue lists operating times ranging from 9.5 hours for the LTD-6700T to 40 hours for the LTK-C7. Actual operating time depends on the selected model, fuel consumption, connected load, and operating conditions.

Which diesel light tower is suitable for construction projects?

Selection depends on the required lighting coverage, mast height, generator output, fuel capacity, and transport arrangements. The available models offer mast heights from 4 to 9 metres. Project engineers should confirm the appropriate configuration based on site requirements.

Are diesel generator light towers portable?

The product range includes trailer configurations with towing hitches and model-specific mobility arrangements. Transport requirements and permitted movement speeds vary, so the selected model's towing and relocation specifications should be reviewed before deployment.

How can I request a light tower generator price in Saudi Arabia?

To request a quotation, provide the project location, required quantity, operating hours, preferred mast height, and lighting configuration. Alrouf can review the requirements and confirm technical documentation, commercial terms, and availability.

Request a Diesel Light Tower Quotation

Looking for a light tower generator in Saudi Arabia?

Contact Alrouf Lighting Technology to discuss technical specifications, model selection, and quotation requirements for your construction or industrial project.

Contact Alrouf — Request a Quote

Related Product: Solar Hybrid Light Tower — Explore an alternative power configuration for temporary site lighting.

No ACF gallery field data found
Check out the instructions in which we explain what can be read from these graphs.
Manual
LIGHTING TOWER
MODEL LTD-6700T LTY-V7 LTK-C7 LTK-V7 LTK-H7
Mast Height (m) 4 8 7.5 8 9
Frequency (Hz) 50 60 50 60 50 50 60 50 60
Rated Voltage (V) 230 240/120 230 240/120 230 230 240/120 230 240/120
Rated Power (kW) 4.5 5.0 6 7 5.4 6 7 6 7
Max Output (kW) 5.0 5.5 7 8 5.94 7 8 7 8
Power Outlet Sockets 1*16A 1*16A 1*16A 1*16A 1*16A 1*16A 1*16A 2*16A 2*16A
Fuel Consumption (L/H) 1.77 2.4 1.85 1.7 1.7
Fuel Tank Capacity (L) 16 30 74 30 40
Fuel Tank Hours 9.5 12.5 40 17 23
Noise Level (7m) dB(A) 72 72 76 76 76 76 76 74 74
Weight (KGS) 200 800 750 800 1630
Dimension in Operation (L x W x H) mm 1500*980*4000 2990x1300x8000 2850x1105x7500 2990x1300x8000 2400x1800x9000
Dimension in Transport (L x W x H) mm disassembly 1100*850*800 1950x1300x1010 1370x750x1000 1950x1300x1010 2400x1800x2540
Load Capacity in 20FT (units) disassembly 20 20 4 4 8 4 4 / /
Load Capacity in 40HQ (units) disassembly 44 44 9 9 24(16) 9 9 4 4
Engine
Engine model LD186FAE LD380 Z482 D1105-E2BG D1105-E2BG
Speed (rpm) 3000 3600 1500 1800 3000 1500 1800 1500 1800
Prime Power (kW) 5.7 6.3 12 14.4 8.3 8.4 10.1 8.4 10.1
Cooling System Air-cooled Water-cooled Water-cooled Water-cooled Water-cooled
Oil Capacity 1.65 4.5 2.5 5.1 5.1
Alternator
Model LA204/2 LA130/4 EK2MCT LT3N-130/4 LT3N-130/4
Continued Power (kVA) 4.5 5.0 7 8 6 7 8 7 8
Excitation mode Self-excitation and constant voltage (AVR) Capacitor exciter
Alternator Insulation H
Protection Grade IP23 IP23 IP23 IP23 IP23
Mast Manual Manual Manual Manual Hydraulic
Section No. (Extended) 3 4 4 4 8
Mast Rotation 180° 359° 359° 359° 359°
Mast Extension Time 35 seconds 45 seconds 45 seconds 45 seconds 14 seconds
Mast Descend Time 20 seconds 30 seconds 30 seconds 30 seconds 10 seconds
Type of Lights Metal Halide Lamp or LED Metal Halide Lamp or LED Metal Halide Lamp or LED Metal Halide Lamp or LED Metal Halide Lamp or LED
Number & Power of the Lights 4*1000W 4*1000W 4*1000W 4*1000W 4*1000W
Mast Lighting & Extension Manual Manual


Electric (Option)

Manual


Electric (Option)

Manual


Electric (Option)

Hydraulic operation
Light Angle Turning Manual Manual Manual Manual Electric
Luminous Flux 4*110000=440000 4*110000=440000 4*110000=440000 4*110000=440000 4*110000=440000
IIIum Area (5 Lux Min) 2500 3900 3000 3900 3900
Lamps Rotation 75° (Manual) 75° (Manual) 75° (Manual) 75° (Manual) 75° (Automatic)
Protection Glass IP33 IP33 IP33 IP33 IP33
Color Temperature 4200K 4200K 4200K 4200K 4200K
Tailer
Braking System / / / / Parking braking
Hitch Ball type/ O Ring option Ball type/O Ring option Ball type/ O Ring option Ball type/ O Ring option Ball type/ O Ring option
Tire Rim Size 252mm 165/R14'' 155R13'' 165/R14'' 185/R14''
Speed <5km/h <80km/h <80km/h <80km/h <80km/h