Al Rouf LED

Twin Head Emergency Light


Warning Sign
Click the relevant product code in the table above to access the Flood Light (IES file) files and the installation instructions for your luminaire.

Twin Head Emergency Light

Product Description

Twin Head Emergency Light is a reliable LED emergency lighting solution designed to provide directional illumination during power failures in industrial and commercial facilities. It features two adjustable LED heads, allowing light to be directed toward evacuation routes, stairways, work areas, machinery zones, and other critical locations.

The BY-Z2035C Twin Head Emergency Light operates in non-maintained mode, activating automatically when the main power supply fails. Its dual adjustable heads make it suitable for applications requiring wider or targeted emergency illumination, particularly in warehouses, factories, workshops, parking garages, and large storage areas.

With a 3-hour emergency duration, 180 lm emergency output, and IP20 protection, this emergency light is designed for indoor emergency lighting applications where dependable backup illumination is required.

Engineering Performance and Technology

The Twin Head Emergency Light BY-Z2035C combines dual-head directional illumination with battery-backed emergency operation.

Key Technical Specifications

  • Model: BY-Z2035C
  • Input Voltage: AC 220–240V, 50/60Hz, 30mA
  • Light Source: LED SMD 2835, 32 pcs
  • Input Power: 2.5W
  • Emergency Duration: 3 hours
  • Emergency Lumen Output: 180 lm
  • Battery Type: Sealed Lead-Acid, 4.0V 2500mAh
  • Recharge Time: 24 hours
  • IP Rating: IP20
  • Operating Temperature: 0°C to 40°C
  • Auto Test: No
  • Certifications: CE & CB-TÜV

The two adjustable LED heads can be positioned independently, allowing the Twin Head Emergency Light to provide targeted illumination across evacuation routes, open areas, and critical zones.

Why Choose a Twin Head Emergency Light?

A Twin Head Emergency Light provides greater flexibility than a fixed-direction emergency light because its two LED heads can be adjusted according to the layout of the installation area.

Key benefits include:

  • Dual adjustable LED heads for targeted emergency illumination
  • 3-hour emergency duration for extended backup lighting
  • Directional lighting for evacuation routes and open areas
  • Suitable for warehouses and high-ceiling industrial spaces
  • Low 2.5W input power
  • Reliable sealed lead-acid battery backup
  • Automatic activation during power failure
  • 180 lm emergency light output
  • Suitable for indoor industrial and commercial environments

Adjustable Twin Head Emergency Lighting

The two heads of the BY-Z2035C Twin Head Emergency Light can be adjusted independently to direct illumination where it is needed.

This configuration can help cover:

  • Emergency pathways
  • Stairways
  • Exit routes
  • Machinery areas
  • Open storage zones
  • Warehouse aisles
  • Industrial work areas

The adjustable design makes the light suitable for installations where a single fixed beam may not provide sufficient directional coverage.

Twin Head Emergency Light Applications

The Twin Head Emergency Light is suitable for indoor facilities that require emergency illumination during power interruptions.

Typical applications include:

  • Warehouses
  • Factories and production lines
  • Industrial workshops
  • Parking garages
  • Large storage areas
  • Industrial service areas
  • Commercial utility spaces

For broader emergency lighting requirements, explore our Emergency Lighting Solutions for additional product configurations.

Twin Head Emergency Light Mounting Options

The BY-Z2035C can be incorporated into emergency lighting layouts according to the building's architectural and installation requirements.

Available fixing configurations include:

  • Ceiling recessed
  • Ceiling surface mounted
  • Semi-recessed
  • Hanging with chain

The appropriate mounting method should be selected according to the ceiling configuration, installation location, and required illumination direction.

Twin Head Emergency Light Operation

The BY-Z2035C operates in non-maintained mode. Under normal conditions, the unit remains connected to the main power supply. When a power failure occurs, the emergency lighting function activates using the internal battery.

The battery provides an emergency duration of approximately 3 hours, helping maintain illumination along critical routes and areas during a power interruption.

Battery and Recharge Performance

The Twin Head Emergency Light uses a sealed lead-acid 4.0V 2500mAh battery.

Key battery characteristics include:

  • Approximately 3 hours emergency duration
  • 24-hour recharge time
  • Automatic emergency operation during power failure
  • Battery-backed LED illumination

Battery performance and emergency duration should be considered when selecting emergency lighting for a specific facility and evacuation layout.

Protection and Operating Environment

The BY-Z2035C has an IP20 protection rating and is designed for indoor applications.

The specified operating temperature range is:

0°C to 40°C

It is therefore suitable for indoor industrial and commercial environments such as warehouses, factories, workshops, and storage areas where the installation conditions fall within the specified operating range.

Compliance and Project Suitability

The Twin Head Emergency Light BY-Z2035C carries CE and CB-TÜV certifications and is suitable for indoor industrial and commercial buildings requiring emergency illumination during power outages.

When selecting emergency lighting for a project, the required illumination area, mounting position, emergency duration, operating mode, and environmental conditions should be considered according to the project design and consultant requirements.

How to Choose the Right Twin Head Emergency Light?

When selecting a Twin Head Emergency Light, consider the following factors:

  1. Coverage requirements – Determine whether the installation requires wide-area or directional emergency illumination.
  2. Adjustability – Two independently adjustable heads can help direct light toward separate critical areas.
  3. Emergency duration – The BY-Z2035C provides approximately 3 hours of emergency operation.
  4. Installation environment – Confirm that the indoor installation conditions are compatible with the IP20 rating and 0°C to 40°C operating temperature.
  5. Mounting configuration – Select the appropriate fixing method according to the ceiling and installation requirements.
  6. Battery requirements – Consider the battery type, emergency duration, and recharge time when planning the emergency lighting system.
  7. Project requirements – Confirm that the selected emergency light meets the consultant's specifications and overall emergency lighting design.

Frequently Asked Questions

What is a Twin Head Emergency Light?

A Twin Head Emergency Light is an emergency lighting fixture equipped with two adjustable LED heads that provide directional illumination during power failures. The two heads can be positioned independently to illuminate different areas.

What is the model of this Twin Head Emergency Light?

The model is BY-Z2035C.

How long does the BY-Z2035C Twin Head Emergency Light operate during a power failure?

The BY-Z2035C provides approximately 3 hours of emergency operation when operating on its internal battery.

Can the two emergency light heads be adjusted separately?

Yes. Each LED head can be adjusted independently, allowing the illumination direction to be positioned according to the installation area and emergency lighting layout.

What battery does the Twin Head Emergency Light use?

The BY-Z2035C uses a sealed lead-acid 4.0V 2500mAh battery.

How long does the battery take to recharge?

The specified recharge time is 24 hours.

What is the emergency lumen output?

The BY-Z2035C provides 180 lm emergency lumen output.

What is the input power of the Twin Head Emergency Light?

The specified input power is 2.5W.

What is the IP rating of the BY-Z2035C?

The BY-Z2035C has an IP20 protection rating and is designed for indoor applications.

What is the operating temperature range?

The specified operating temperature range is 0°C to 40°C.

Does the BY-Z2035C have an auto-test function?

No. The specified Auto Test function is not available on this model.

Is the Twin Head Emergency Light suitable for warehouses?

Yes. The BY-Z2035C is suitable for warehouses, particularly where adjustable directional emergency illumination is required for aisles, storage areas, and emergency routes.

Where can Twin Head Emergency Lights be used?

Typical applications include warehouses, factories, production lines, industrial workshops, parking garages, and large storage areas.

Is the BY-Z2035C maintained or non-maintained?

The BY-Z2035C operates in non-maintained mode, activating its emergency illumination when the main power supply fails.

What certifications does the BY-Z2035C have?

The BY-Z2035C carries CE and CB-TÜV certifications.

Explore more certified emergency lighting solutions from Al Rouf LED, designed for commercial and industrial safety applications. For technical support, product recommendations, or project quotations, contact our team to help you select the right emergency lighting system for your project.

No ACF gallery field data found
Check out the instructions in which we explain what can be read from these graphs.
Manual
crossmenu linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram