Al Rouf LED

Hazardous Area Lighting: How to Choose Lights for Zone 1, 2, 21 and 22

To select hazardous-area lighting, match the exact luminaire’s certification, equipment protection level, gas or dust group, temperature limits and installation conditions to the approved area classification.

The zone number is a starting point. It does not, by itself, establish that a particular light is suitable.

For contractors, consultants and procurement teams in Saudi Arabia and the GCC, a clear selection process helps connect the project specification to the equipment being quoted.

What Does Hazardous Area Classification Mean?

Hazardous area classification identifies locations where explosive atmospheres may occur and where equipment needs appropriate protection against becoming an ignition source.

The classification considers the likelihood and persistence of an explosive atmosphere. Gas, vapour and mist hazards use Zones 0, 1 and 2. Combustible dust-cloud hazards use Zones 20, 21 and 22.

Obtain the approved classification drawings and supporting information from the responsible project team. A supplier should use those requirements to assess the proposed equipment.

For an introduction to lighting types and protection terminology, read our Explosion-Proof Lighting Guide.

What Is the Difference Between Zone 1, 2, 21 and 22?

The key distinction is the type of explosive atmosphere and how likely it is to occur.

ZoneAtmosphereGeneral meaning
Zone 1Gas, vapour or mistAn explosive atmosphere is likely to occur occasionally during normal operation
Zone 2Gas, vapour or mistAn explosive atmosphere is unlikely during normal operation and, if it occurs, persists only briefly
Zone 21Combustible dust cloudAn explosive atmosphere is likely to occur occasionally during normal operation
Zone 22Combustible dust cloudAn explosive atmosphere is unlikely during normal operation and, if it occurs, persists only briefly

These are classification definitions. They do not prescribe a universal lighting wattage, mounting height or fixture format.

Zones 0 and 20 address more persistent explosive atmospheres. Do not assume that equipment selected for Zones 1 or 21 is suitable for those locations.

Which Equipment Protection Level Matches Each Zone?

Equipment Protection Level, or EPL, identifies the protection level assigned to equipment under the relevant assessment.

The usual zone-to-EPL relationship is:

Installation zoneNormally applicable EPL options*
Zone 1Ga or Gb
Zone 2Ga, Gb or Gc
Zone 21Da or Db
Zone 22Da, Db or Dc

Subject to the applicable selection rules, risk assessment, equipment documentation and project requirements. Meeting the EPL requirement does not resolve the other selection checks.

For example, equipment carrying only a Gc protection level should not be accepted for Zone 1 simply because it is described as “explosion-proof.”

Can the Same Light Be Used for Gas and Dust Hazards?

Some luminaires have documented protection for both gas and dust applications. Others do not.

Check the separate markings and supporting documents for each hazard. Gas suitability does not automatically establish dust suitability.

If both hazards are relevant, ask the responsible engineer to confirm the full selection requirements. The assessment must also consider temperature limits and any restrictions associated with the intended installation.

What Should You Check Beyond the Zone Number?

A useful technical review covers the complete offered model.

Gas or Dust Group

Confirm that the equipment group covers the substances identified in the project documentation.

Do not select a fixture using the zone number while leaving the gas or dust group unspecified.

Temperature Limits

Check the relevant temperature classification or maximum surface temperature against the project’s hazardous-substance assessment.

Also confirm the permitted ambient-temperature range. Surface-temperature limits and ambient-temperature limits describe different requirements.

Protection Techniques and Certificate Conditions

Request the complete Ex marking and relevant certificate schedule.

The documentation should identify the protection techniques, equipment protection level and any specific conditions affecting selection or use. IECEx guidance treats these as distinct elements of the equipment marking and certificate.

Environmental Conditions

Give suppliers the actual site conditions, including relevant heat, sunlight, dust, water and corrosive exposure.

For Saudi and GCC projects, “suitable for local weather” is less useful than defined operating conditions and a documented response.

How Do You Choose Between Floodlights, High Bays and Linear Lights?

Choose the lighting format around the task, then verify the hazardous-area suitability of the exact model.

Fixture formatLighting-design considerations
FloodlightArea coverage, aiming, beam distribution and glare
High bayMounting height, spacing, obstructions and maintenance access
Linear lightWalkway or equipment layout, distribution and mounting arrangement

Alrouf lists the Ex-Proof Flood Light A-Series, B-Series Highbay and Ex-Proof Linear Light.

Review the product information and ask the team to confirm the model, configuration and documentation appropriate to your specification.

What Information Should You Include in a Lighting Enquiry?

Send enough information for the supplier to assess both equipment suitability and lighting performance.

Enquiry itemInformation to provide
Area classificationApproved drawing, zone and relevant hazard information
Project specificationRequired standards, documentation and approval process
Lighting taskArea dimensions, mounting height and required illumination
Electrical supplyVoltage and frequency
EnvironmentAmbient temperatures and relevant exposure conditions
InstallationMounting, cable entries and accessory requirements
Commercial scopeQuantities, delivery location and required date

For replacement work, include the existing fixture details and any restrictions affecting access, wiring or mounting.

Ask the supplier to identify assumptions, exclusions and departures from the specification before placing the order.

What Documents Should You Review Before Approval?

Request:

  • The complete model and ordering code.
  • Technical datasheet and Ex marking.
  • Relevant certificates and associated schedules.
  • Installation and maintenance instructions.
  • Photometric files where lighting calculations are required.
  • Details of mounting and cable-entry components.
  • Documentation covering optional batteries or controls.
  • A compliance response against the project specification.

Where IECEx certification is proposed, check the certificate against the official IECEx online certification system. Confirm that it covers the offered equipment and configuration.

Frequently Asked Questions

Can Zone 1 lighting be used in Zone 2?

Equipment meeting Zone 1 protection requirements may also meet the protection-level requirement for Zone 2. However, confirm the complete marking, gas group, temperature limits, certificate conditions and installation requirements before approving it.

Can Zone 2 lighting be used in Zone 1?

Equipment suitable only for Zone 2 should not be accepted for Zone 1. Review the exact model’s protection level and certification.

Are Zone 21 and Zone 22 gas classifications?

No. They refer to explosive atmospheres involving combustible dust clouds. Zones 1 and 2 address gas, vapour or mist atmospheres.

Does a higher wattage make a light suitable for a different zone?

No. Wattage does not establish hazardous-area suitability. Select the required protection characteristics separately from the lighting performance.

Should I choose lighting before the area classification is available?

The classification is a necessary input to final equipment selection. Obtain the approved requirements before accepting a fixture for the classified location.

Discuss Your Hazardous-Area Lighting Specification

Explore Alrouf’s hazardous-area lighting range and prepare your classification information, layout, quantities and installation conditions.

Contact Alrouf to confirm available configurations, supporting documents and quotation scope for your project.

crossmenu linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram