What Is the Alrouf AR-CM-001 Conductor Marking Light?

 Alrouf AR-CM-001 is a conductor-mounted LED obstruction light for overhead high-voltage power lines. It harvests energy through electromagnetic induction and provides red warning illumination with 360° horizontal coverage. Its integrated photocell controls operation according to ambient light, while the IP66-rated enclosure protects the lighting assembly.

Key Features and Benefits

  • Inductively powered: Harvests energy from the magnetic field surrounding the current-carrying conductor.
  • Red LED illumination: Low-intensity Type B lighting, as described in the catalogue.
  • 360° horizontal coverage: Provides warning illumination around the conductor.
  • Automatic light control: Integrated photocell with a listed activation threshold of 50 lux.
  • IP66 protection: Outdoor enclosure protection specified in the catalogue.
  • Durable construction: Stainless steel frame, die-cast aluminium components and a UV-protected polycarbonate lens.
  • Long service life: Listed lifespan of up to 100,000 hours.
  • Five-year warranty: As stated in the product catalogue.

How the Inductively Powered Light Works

The AR-CM-001 uses electromagnetic induction to power its LED assembly. Current flowing through the overhead conductor creates a surrounding magnetic field. The light’s induction assembly converts energy from this field into electrical power.

An integrated photocell controls day and night operation. Compatibility must account for the line’s operating current as well as conductor diameter and voltage.

Learn more about how conductor marking lights work on overhead power lines.

Applications for Overhead Power Lines

The catalogue identifies applications on overhead power transmission lines, including locations associated with:

  • Airports.
  • Heliports.
  • River crossings.
  • Overhead power line corridors.

The conductor-mounted design places the warning light directly on the overhead wire to help identify its position to aircraft.

Technical Specifications

Specification Catalogue information
Model AR-CM-001
Light source LED
Light colour Red
Obstruction light classification Low intensity, Type B
Horizontal beam 360°
Vertical beam 10°
Compatible conductor diameter 15–40 mm
Line voltage suitability Up to 500 kV
Operating line frequency 50/60 Hz
Power consumption Less than 5 W
Photocell activation 50 lux
Ingress protection IP66
Frame and body materials Stainless steel, aluminium alloy and polycarbonate
Lens material Polycarbonate
Weight 4.5 kg
Listed service life Up to 100,000 hours
Listed warranty Five years

Conductor Compatibility and Mounting

The light is designed for conductor diameters from 15 mm to 40 mm. The catalogue describes mounting features including self-locking screws, anti-drop provisions and an anti-rotation nut.

Confirm the conductor dimensions and electrical operating conditions when specifying the product.

For a selection checklist, read how to choose an aviation obstruction light for overhead power lines.

Compliance Information and Product Documents

The catalogue states conformity with ICAO Annex 14, Volume I, Chapter 6, for low-intensity Type B obstruction lighting. It also references FAA AC 150/5345-43 and FAA Type L-810.

These references describe the catalogue’s stated compliance. Supporting documents should be reviewed against the requirements of the project.

Frequently Asked Questions

How is the AR-CM-001 powered?

It harvests energy by electromagnetic induction from the current flowing through the conductor.

Which conductor diameters does it fit?

The catalogue specifies conductor diameters of 15–40 mm.

Does it operate automatically at night?

The integrated photocell controls operation according to ambient light. The listed activation threshold is 50 lux.

Does it work when the power line is de-energized?

The described power source depends on current flowing through the conductor. The catalogue does not specify a backup power source or operation during a line outage.

What warranty does the catalogue list?

The catalogue lists a five-year warranty and a service life of up to 100,000 hours.

How can I request a price in Saudi Arabia?

Contact Alrouf with the required quantity, conductor diameter, line voltage, operating current and delivery location.

For help preparing your enquiry, see our obstruction light price and quotation guide for Saudi Arabia.

Request an Obstruction Light Quote in Saudi Arabia

Contact Alrouf about the AR-CM-001 for your overhead power line project. Include your technical requirements, required quantity and delivery location to support product selection and quotation.

Request a Quote

No ACF gallery field data found
Check out the instructions in which we explain what can be read from these graphs.
Manual
crossmenu linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram